Most authorities now agree that vapor barriers are important under certain conditions but not necessarily as a whole house solution for every home.
Vapor barrier over concrete roof deck.
The midwest roofing contractors association mrca is advising a vapor retarder of less than 0 01 perm is necessary over new concrete roof decks.
If a roof system is installed over a concrete deck without a vapor barrier the moisture in the concrete will likely dry into the roof insulation.
From a practical standpoint a vapor retarder of less than 0 01 perm is effectively a vapor barrier almost no moisture passes through to the roof system above.
Typically a vapor retarder has to have a perm rating of 1 0 or less to be successful.
Another exception is a class i vapor retarder should be installed over a new concrete deck to prevent the moisture in the concrete from drying into the roof system.
In circumstances where conditions inside a home or office are much different than outdoor conditions water.
Roof system designs using mechanical fasteners penetrating a vapor retarder should be avoided.
Despite this concern for concrete decks a self adhering vapor barrier protects the insulation and provides a temporary roof.
Likewise a self adhering vapor barrier will not stick to concrete over the long term.
The moisture in the concrete will release into the glue causing the self adhering vapor barrier to fail.
Exceptions to this idea include roofs over indoor swimming pools or other high humidity producing activities and over new concrete roof decks to prevent the moisture in the concrete from drying into the roof system.
A vapor retarder is a material or system that is designed as part of the roof system to substantially reduce the movement of water vapor into the roof system where it can condense.
The old vapor barrier was attached with hot asphalt and it s really fused to the concrete deck.
Here s a key takeaway all vapor retarders block air but not all air barriers block vapor diffusion.
When we use a vapor retarder in a roof system it will also act as an air barrier as long as it is sealed at all perimeters and penetrations and is tied to the wall air barrier.
Everyone knows that water in roof systems is never a positive.
In a low slope roof assembly the vapor retarder is normally installed under the primary roof insulation.
Rolling out a course of the new vapor barrier.
This method is shown in the image above.
A vapor retarder is commonly installed on the warm interior side of a roof or wall.
Therefore one will often see it installed directly on a roof deck such as a concrete or wood deck or on a continuous substrate such as gypsum board or wood panels that is installed directly over a metal deck.